SECURE Energy Services provides a unique cost-saving advantage for fluid storage with our patented Target Tank™, a dual containment fluid storage tank. The primary purpose of the industrial tank is to store oil-based drilling fluids on well sites during drilling operations. The Target Tank™ can also be utilized for other applications where dual containment is required, such as frac jobs or production workovers. SECURE currently has a fleet of over 360 Target Tanks available in Western Canada, with service centres in Grande Prairie, Edson, Rocky Mountain House and Fort St. John.
The Target Tank™ is approved by the Alberta Energy Regulator for on-site oil based fluid storage without a berm. In addition, the Target Tank™ meets the Alberta Energy Regulator storage requirements without the need for a dike when drilling or operating within 100m of a waterbody.
Tank Features
- Overflow protection
- Digital gauges with overfill alarms
- Unique manifold design for better circulation of fluids
- Double-walled tanks do not require secondary containment berm system
- 20 HP Pioneer P3 pump transfer fluid at +/- 1.5 m³/minute via 3” plumbing.
- No picker or pilot cards required
- No liner purchase
- No rig matting
- No access stairs
Equipment Summary
- 60 m³ Dual Containment Master Tank (stores pump, line crossing and hoses)
- 75 m³ Dual Containment Fluid Storage Tank
- Fire Extinguishers
- 5 m³ Dual Containment Evaporator Tanks
- 600V TO 480V Transformers
- Fluid Transfer Pumps
- Line Crossings
- Rig matting
Tank Specifications
| Metric | Imperial |
Length | 13.72 m | 45.0 ft |
Width | 3.20 m | 10.5 ft |
Height | 3.35 m | 11.0 ft |
Dry Weight | 16,239 kg | 36,000 lbs |
Safety Benefits
Reduced Slipping and Tripping Hazards
- No bermed area to keep clear of snow or water
- No hoses on the ground
Reduced Overhead Hazards
- No overhead crane work
- No high reaches during cleaning
Reduced Spill Hazard
- No leaks occur due to plumbing over tank
- Front drip trays contain minor spills
Superior Lighting
- 2’ fluorescent lights
Reduced Accident Hazards
- Less truck activity
Reduced Highway Hazards
- Drivers and swampers work within allowable hours
Reduced Lifting Hazards
- Fluid transfer pump is bolted to tank
- Hoses are positioned at chest level
Logistical Benefits
- No picker truck required for set-up
- No pilot truck required (BC)
- Loads spotted on location in one hour
- Utilizes tri or quad-fluid hauling trailers
- Eliminates extra trip to new location to setup berm system and starter tanks
- Reduces stand-by time for fluid hauling trucks
Environmental Benefits
- Smaller footprint for tank farm
- No requirement for liner disposal
- Less trucking = less emissions
- Zero ground disturbance